Afikim Afi-lite Plus Manual de usuario

Busca en linea o descarga Manual de usuario para De medición, control y control Afikim Afi-lite Plus. Afikim Afi-lite Plus User manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 39
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
A
fi-lite Plus
Milk Meter
(Product number 4098999)
User Manual
¬
http
February 27, 2003
Kibbutz Afikim, 15148, ISRAEL
+972-4-675-4811
+972-4-675-1862
www.afimilk.co.il
This manual P/N 9040310
TM
Vista de pagina 0
1 2 3 4 5 6 ... 38 39

Indice de contenidos

Pagina 1 - Milk Meter

Afi-lite PlusMilk Meter (Product number 4098999) User Manual ¬httpFebruary 2

Pagina 2

Afi-lite User Manual P/N 9040310 4+ Key functions The keys, and their functions, are described below. At the press of each key side lights glow on

Pagina 3 - Warnings

February 27, 2003 Afi-lite User Manual 5 Operating the Afi-lite Milk Meter This section contains instructions on the milking process and on displayi

Pagina 4

Afi-lite User Manual P/N 9040310 6+++ +5. To start milking, press the key. This starts the vacuum and releases the cluster. If a co

Pagina 5 - Updates

February 27, 2003 Afi-lite User Manual 7Cow and Milk Information Accessible from Afi-lite Important information on each cow and her milk can be rea

Pagina 6

Afi-lite User Manual P/N 9040310 8Milk Flow Rate (average): Press and to see the average milk flow rate of the cow being milked. Milking Time

Pagina 7 - Chapter 1: Overview

February 27, 2003 Afi-lite User Manual 9Messages, Milking Codes and Alerts Milking codes, and messages are a means of communication between milkers

Pagina 8

Afi-lite User Manual P/N 9040310 10Codes 5, and 8 – Afi-lite Alerts Of the eight “milking codes” (1-8), most codes can be used to determine situati

Pagina 9

February 27, 2003 Afi-lite User Manual 11 Codes: Display of Code Before Milking During Milking After Cluster Removal Code Num-ber Situation that C

Pagina 10 - Key functions

Afi-lite User Manual P/N 9040310 12Messages Messages can be sent from an Af-lite milk meter to the computer. A message can be sent to the computer

Pagina 11 - Afi-lite User Manual

February 27, 2003 Afi-lite User Manual 13 Example A: To send a message to the computer that cow 1299 is limping (if the number 34 is designated as

Pagina 12

Afi-lite User Manual P/N 9040310 b

Pagina 13

Afi-lite User Manual P/N 9040310 14

Pagina 14

February 27, 2003 Afi-lite User Manual 15 Side B Side A Chapter 3: Setting Afi-lite Parameters Parameters are variables that must be given a value

Pagina 15 - Milking Codes

Afi-lite User Manual P/N 9040310 16Automatic Cluster Removal (ACR) Parameters The Afi-lite milk meter detects when the milk flow rate from the cow h

Pagina 16 - Alerts

February 27, 2003 Afi-lite User Manual 17 Changing Values of Cluster Removal Parameters To change the values of cluster removal time spans, proceed

Pagina 17

Afi-lite User Manual P/N 9040310 18

Pagina 18 - Messages

February 27, 2003 Afi-lite User Manual 19 Chapter 3: Cleaning Routine This chapter describes general cleaning guidelines, warnings, and recommendat

Pagina 19

Afi-lite User Manual P/N 9040310 20General Instructions The cleaning cycle of the AfiFlo milk meter body is executed in the same manner as any stand

Pagina 20

February 27, 2003 Afi-lite User Manual 21 Cleaning Cycle There are various cleaning systems and procedures in use in milking parlors. Nevertheless,

Pagina 21

Afi-lite User Manual P/N 9040310 22Acid Wash Do this acid wash once a week, or more frequently, where necessary. This acid wash is not in place of

Pagina 22 - ACR Parameters

February 27, 2003 Afi-lite User Manual 23 Chapter 4: Milk Meter Body and Fat Sampler This chapter contains information about: • The basic structu

Pagina 23

February 27, 2003 Afi-lite User Manual cTable of Contents Chapter 1: Overview ...

Pagina 24

Afi-lite User Manual P/N 9040310 24The Milk Meter Body, Structure and Components ValveMilk inlet Electrode Electrode Electr

Pagina 25 - Chapter 3: Cleaning Routine

February 27, 2003 Afi-lite User Manual 25 The AfiFo milk meter body is a plastic container made up of three main parts: • The Upper Cover and Inlet

Pagina 26 - General Instructions

Afi-lite User Manual P/N 9040310 26Partial Parts List of Afi-lite Plus: Cable length optionItem Standard cable lengths Longer body cables Longer

Pagina 27 - Cleaning Cycle

February 27, 2003 Afi-lite User Manual 27

Pagina 28 - Cleaning Exterior Surfaces

Afi-lite User Manual P/N 9040310 28The Fat Sampler International dairy authorities, as well as most local dairy authorities, require the sampling of

Pagina 29 - Fat Sampler

February 27, 2003 Afi-lite User Manual 29 Chapter 6: Troubleshooting The Afi-lite milk meter is equipped with alerts to advise milkers of problemat

Pagina 30

Afi-lite User Manual P/N 9040310 30 Output #2: Solenoid that controls removal device Output #3: Solenoid that controls vacuum shut-off to cluster

Pagina 31

February 27, 2003 Afi-lite User Manual 31 Index A alerts premature cluster removal, 29 B back-flush assembly, 25 F fat sampler, 25 arrow on head of,

Pagina 34 - The Fat Sampler

Afi-lite User Manual P/N 9040310 d

Pagina 35 - Chapter 6: Troubleshooting

February 27, 2003 Afi-lite User Manual eUpdates to the Afi-lite Plus user manual Through out this manual, the term Afilite milk meter refers to the

Pagina 36 - More Troubleshooting

Afi-lite User Manual P/N 9040310 f

Pagina 37

February 27, 2003 Afi-lite User Manual 1 Chapter 1: Overview The Afi-lite milk meter is installed at every milking point and performs the following

Pagina 38

Afi-lite User Manual P/N 9040310 2

Pagina 39

February 27, 2003 Afi-lite User Manual 3 The Afi-lite milk meter control box Chapter 2: The Milk Meter Control Box This chapter describes operatio

Comentarios a estos manuales

Sin comentarios